关注公众号

关注公众号

手机扫码查看

手机查看

喜欢作者

打赏方式

微信支付微信支付
支付宝支付支付宝支付
×

Invivo evaluation ofdrug lead candidates by intravenous continuous infusion

2019.4.25

In vivo evaluation of drug lead candidates by intravenous continuous infusion

Sang Ho Lee

Wesley Shoop

Bruce Michael

Thomas Felcetto

Sheo Singh

Jun Wang , jun_wang2@merck.com, Merck Research Laboratories

Related Journal & Article Information

Manuscript: 2006-01-00990C
 

Journal: Nature
 

Article Title: Platensimycin is a selective FabF inhibitor with potent antibiotic properties
 

Introduction

Numerous in vitro assays have been devised to identify potential drug leads with potent activities. However, most of these lead candidates fail in the preclinical stage due to lack of adequate in vivo efficacy in animal models. One main reason for such high failure rate is poor pharmacokinetics of the candidate in the host. Herein we describe the use of intravenous continuous infusion to circumvent the inherent poor pharmacokinetics of a given candidate to show in vivo ‘proof of concept’ in the early stage of drug discovery(ref. 1). Continuous infusion allows for a putative drug candidate to be maintained at a specified steady-state drug concentration in the host blood and other organs for a prolonged duration, which is not possible by bolus administration. Maintenance of desired steady-state levels of drug gives sufficient time for the drug candidate to confer in vivo efficacy. In an effort to provide greater pharmacokinetic coverage to the lead antimicrobial candidate, platensimycin, we instituted such intravenous continuous infusion with systemic Staphylococcus aureus infection in a murine animal model. This method was successfully used to demonstrate the potent in vivo antibacterial activity of platensimycin against systemic S. aureus) infection.
 

Materials

Reagents

For this study, 25-30 gram 10 week old CD-1 mice were implanted with jugular vein catheter (JVC) by Taconic Farms. Mouse harness, counter-balance arm and PE 20 tubing were purchased from Instech Solomon. 0.5 inch hollow stainless connector was purchased from Access Technologies. S. aureus MB 2865 (Smith Strain), Trypticase soy broth (TSB), 125 mL baffled flask, and Mannitol agar plates (Becton Dickinson) were used for this study.
 

Equipment

The main equipment used in the intravenous continuous infusion study is a multi-syringe infusion pump capable of handling multiple 5 mL syringes (Lomir Biomedical) and a 37°C shaking incubator.
 

Time Taken

This experiment requires total of 3 days, 1 day to set up infusion apparatus cages, 1 day of infusion, and 1 day of incubation for final plating enumeration. 
 

Procedure

1) Virulent S. aureus MB 2865 (Smith strain) was grown overnight with aeration in TSB medium. 
2) Bacteria were harvested and washed with fresh TSB and serially diluted to achieve an infective inoculum of 4 × 103 CFU/mL in 5% hog gastric mucin, and 0.5 mL was used to infect intraperitoneally. 
3) The infected mice were anesthetized using isoflurane (Abbott). 0.5 inch hollow connectors were attached to the external section of the JVC catheter and the mice were subsequently harnessed to the counter-balance arm inside a mouse cage. 
4) Fluid primed PE 20 tubings attached to individual syringes on the infusion pump were connected to the mice through the 0.5 inch hollow connector. 
5) The infusion pump was initiated for 24 hours at a flow rate of 0.1 mL/hour. 
6) Blood samples are taken by tail vein to determine serum drug concentration during the infusion. 
7) After the 24 hour period, the mice were euthanized and the kidneys were aseptically removed and homogenized. 
8) Serial dilutions of the homogenates were plated on Mannitol plates and incubated overnight at 37°C. 
9) Bacterial counts were enumerated (ref. 2).
 

Troubleshooting

Tubing may become detached due to radical mouse movement. When it happens, stop the pump temporarily, gently remove harness and reattach the tubing to the 0.5 inch hollow connector making sure no air is in the tubing. Restart the pump and continue observation.
 

Critical Steps

The compound to be infused must be soluble and filtered through 0.22 µM filter to remove precipitants. The harness must be properly attached to the mouse to restrict access to the exposed tubing; otherwise the mouse will chew the tubing. However, the harness should not be on too tight to restrict breathing, check each individual mouse carefully prior to connecting to the infusion pump.
 

Anticipated Results

Intravenous continuous infusion of platensimycin was applied at 150, 100, 50 and 25 µg/hr for 24 hours to maintain a variety of steady-state levels in the host plasma. Maintenance of 100 and 150 µg/hr steady state levels resulted in greater than 4-5 log (104 -105 fold) reduction of bacterial load in the kidneys of treated mice compared to the vehicle treated controls (Fig. 1). The corresponding plasma drug concentration of 100, 50, and 25 µg/hr continuous infusion doses were about 0.6, 0.32 and 0.17 µg/mL, respectively (Fig. 2)
 

References

1. Shoop, W. L. et al. Anthrax lethal factor inhibition. PNAS 102, 7958-7963 (2005).
2. Abruzzo, G. et al. Evaluation of the echinocandin antifungal MK-0991 (L-743,872): efficacies in mouse models of disseminated aspergillosis, candidiasis, and cryptococcosis. Antimicrob. Agents Chemother. 41, 2333-2338 (1997).

Acknowledgements

 

Keywords

Platensimycin, continuous infusion, in vivo efficacy, Staphylococcus aureus.
 

Figure 1

In vivo efficacy of platensimycin

Dosing at 50 µg/hr showed small reduction of viable S. aureus cells from the infected kidney. However, reductions of 4 and 5 log were achieved with 100 and 150 µg/hr, respectively. Dosing of 150 µg/hr showed 40% of the kidneys with no viable S. aureus while dosing of 100 µg/hr exhibited 20% of the kidneys without detectable viable S. aureus.


 

Figure 2

Monitoring of plasma drug concentration

Plasma concentration of platensimycin was monitored during continuous infusion at a rate of 25 (filled circle), 50 (open circle) or 100 µg/hr (closed triangle).


 


推荐
热点排行
一周推荐
关闭