K36 低压配电用器具 标准查询与下载



共找到 120 条与 低压配电用器具 相关的标准,共 8

The document refers to sizes of flush-type house connection boxes for underground service.

House connection boxes for underground service - Flush-type house connection boxes for underground service for HRC-fuses size 00 up to 100 A 500 V and size 1 up to 250 A 500 V

ICS
91.140.50
CCS
K36
发布
1998-10
实施

  本标准规定了自耦减压起动控制装置的使用类别为AC-3(用于笼型感应电动机的起动和在运转中的分断)。它既不能用于AC-4(用于笼型感应电动机的起动、点动、反接制和反转),也不能用于频繁通断的工作制或电动机的突然反转。   本标准规定了自耦减压起动控制装置的使用条件、类别、技术要求、试验方法、检验规则、标志、包装、运输与贮存。   本标准适用于频率50Hz(或60Hz),额定电压交流1000V(1140V)及以下的自耦减压起动控制装置,该起动装置用来起动并加速交流笼型感应电动机至额定速度,并对电动机和与它相关联的电路的操作、过载、短路进行保护,以及人为地使电动机停止。   注:1140V仅限于煤矿井下使用。

Auto-transform start controlgear

ICS
29.100.20
CCS
K36
发布
1998-05-26
实施
1998-12-01

The document applies for multicore systems for connecting and current distributing for more than one electric circuit for projectors for use in production workstations for film and television.

Electric power-distribution equipment for production workstations for film and television - Part 8: Multicore systems

ICS
29.120.30;97.200.10
CCS
K36
发布
1998-04
实施

Cubicle type high voltage power receiving units

ICS
29.240.10
CCS
K36
发布
1998-03-20
实施

Customer distribution boards and meter panels AC 400 V - Main line branch terminals

ICS
29.120.20
CCS
K36
发布
1998-03
实施
1998-03-01

本标准规定了倒顺开关的基本性能和要求。包括:型号、规格、标志、正常工作条件和安装条件、技术要求、试验方法、检验规则。 本标准适用于交流50 Hz、额定工作电压380V及以下、额定工作电流25 A及以下的HY2等系列倒顺开关。该开关主要用作直接通断单台鼠笼式感应电动机,使其正转、反转和停止。

Inverted switch

ICS
CCS
K36
发布
1997-12-17
实施
1998-02-01

A method of temperature-rise assessment by extrapolation for partially type-tested assemblies (PTTA) of low-voltage switchgear and controlgear (IEC 60890:1987 + Corrigendum 1988 + A1:1995); German version HD 528 S2:1997

ICS
29.130.20
CCS
K36
发布
1997-11
实施
1997-11-01

本标准适用于额定电压不超过交流440V、额定电流不大于32A、家用及类似环境用暗装式的电器附件,如开关、插座、电铃按钮等所用的面板、调整板和安装盒。 电器附件暗装用的面板、调整板和安装盒,适于在一般不超过35℃,偶尔会达到40℃的环境温度下使用。 本标准亦适用于安装或悬吊照明设备用的安装盒。 本标准不适用于装有过电流保护装置的组合电器附件,也不适用于汇流条线槽型的电器附件。

Panels, adjusting plates and mounting boxes intended to be used in concealed installation of electric accessories

ICS
97.030
CCS
K36
发布
1997-07-25
实施
1997-10-01

Covers wired cabinets for use in accordance with the American National Standard National Electrical Code. Covers display cases and special-purpose cabinets containing electrical wiring, with or without illumination by incadescent or electric-discharge lamps, including quick-starting and high-voltage lamps operating in multiple at potential of 1000 volts or less.

Wired cabinets

ICS
29.130.10
CCS
K36
发布
1997-03-26
实施

Low-voltage mains installations.

ICS
29.020;29.240.01
CCS
K36
发布
1996-09-01
实施
1996-09-05

Specifies requirements or cable trunking and ducting systems intended for mounting on walls or ceilings. The systems are intended to be mounted directly on walls or ceilings, flush or semiflush, or indirectly on walls or ceilings.

Cable trunking and ducting systems for electrical installations - Part 2: Particular requirements - Section 1: Cable trunking and ducting systems intended for mounting on walls or ceilings

ICS
29.120.10
CCS
K36
发布
1996-01
实施
2017-03-24

Junction boxes - 16 A, 500 V, degree of protection IP 56

ICS
47.020.60
CCS
K36
发布
1995-08
实施

Low voltage panelboards for household use

ICS
29.130.01
CCS
K36
发布
1995-03-01
实施

Lighting busways

ICS
29.120.10
CCS
K36
发布
1995-01-01
实施

Dead-front switchboards

ICS
29.120.60
CCS
K36
发布
1994-02
实施

These requirements cover panelboards to be employed in accordance with the National Electrical Code, NFPA 70. These requirements cover panelboards for the control and protection of electric lighting and appliance branch circuits, and power circuits, including feeder distribution panelboards. They also cover units specifically designed for panelboard assembly. These requirements do not cover: a) Distribution equipment which sole function is the automatic or nonautomatic transferring of one or more load conductor connections from one power source to another. Reference the Standard for Transfer Switch Equipment, UL 1008. b) Factory wired assemblies of industrial control equipment intended to control industrial processes. Reference the Standard for Industrial Control Panels, UL 508A. c) Distribution equipment containing only one circuit subdivision, unless also provided with a meter socket. See 6.5.1. Reference the Standard for Molded-Case Circuit Breakers, Molded- Case Switches and Circuit-Breaker Enclosures, UL 489. d) Distribution equipment intended to serve as a means for distributing power required to operate mobile or temporarily installed equipment. Reference the Standard for Power Outlets, UL 231. e) Factory wired assemblies of controllers, timers, temperature regulating equipment and such, intended for control of equipment for use with swimming pools, hot tubs, and/or spas. Reference the Standard for Electric Hot Tubs, Spas and Associated Equipment, UL 1563. f) Factory wired assemblies intended for the control of Architectural and Floating Fountains. Reference the Standards for Motor-Operated Water Pumps, UL 778, Underwater Lighting Fixtures, UL 676 and Industrial Control Panels, UL 508A. g) Portable power distribution equipment. Reference the Standard for Portable Power-Distribution Equipment, UL 1640.

Panelboards

ICS
29.130.99
CCS
K36
发布
1993-12-08
实施

Flat-plate photovoltaic modules and panels

ICS
27.160
CCS
K36
发布
1993-05
实施

Wired cabinets

ICS
29.260.00
CCS
K36
发布
1993-04
实施

The document is intended to ensure proper installation and connection of built-in equipment up to 63 A with dimensions in accordance with DIN 43880 into consumer units in accordance with DIN VDE 0603.

Consumer units for built-in equipment up to 63 A

ICS
1750
CCS
K36
发布
1992-11
实施

The document applies to incoming supply and metering ACS 400 V (630 A secondary metering). The object is to lay down the built-in components in accordance with EN 60439-4-1990, sub-clause 9.1 and the dimensions.#,,#

Assemblies for Construction Sites (ACS); incoming supply and metering ACS 400 V, 630 A; secondary metering

ICS
29.120.60
CCS
K36
发布
1992-07
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号