L86 通用电子测量仪器设备及系统 标准查询与下载



共找到 257 条与 通用电子测量仪器设备及系统 相关的标准,共 18

This part of CISPR 16 specifies the methods of measurement of radiated disturbance phenomena in the frequency range of 9 kHz to 18 GHz. The aspects of measurement uncertainty are specified in CISPR 16-4-1 and CISPR 16-4-2.

Specification for radio disturbance and immunity measuring apparatus and methods - Methods of measurement of disturbances and immunity - Radiated disturbance measurements

ICS
33.100.10; 33.100.20
CCS
L86
发布
2010-07-31
实施
2010-07-31

This part of CISPR 16 specifies the methods of measurement of radiated disturbance phenomena in the frequency range of 9 kHz to 18 GHz. The aspects of measurement uncertainty are specified in CISPR 16-4-1 and CISPR 16-4-2.

Specification for radio disturbance and immunity measuring apparatus and methods. Methods of measurement of disturbances and immunity. Radiated disturbance measurements

ICS
33.100.10;33.100.20
CCS
L86
发布
2010-07-31
实施
2010-07-31

This part of CISPR 16 specifies the characteristics and performance of equipment for the measurement of radio disturbance in the frequency range 9 kHz to 18 GHz. In addition, requirements are provided for specialized equipment for discontinuous disturbance measurements. The specifications in this standard apply to EMI receivers and spectrum analyzers. The term “measuring receiver” used in this standard refers to both EMI receivers and spectrum analyzers. Further guidance on the use of use of spectrum analyzers and scanning receivers can be found in Annex B of any one of the following standards: CISPR 16-2-1, CISPR 16-2-2 or CISPR 16-2-3.

Specification for radio disturbance and immunity measuring apparatus and methods. Radio disturbance and immunity measuring apparatus. Measuring apparatus

ICS
33.100.01;33.100.10
CCS
L86
发布
2010-04-30
实施
2010-04-30

This part of CISPR 16 specifies the characteristics and performance of equipment for the measurement of radio disturbance in the frequency range 9 kHz to 18 GHz. In addition, requirements are provided for specialized equipment for discontinuous disturbance measurements. NOTE In accordance with IEC Guide 107, CISPR 16-1-1 is a basic EMC standard for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of the EMC standard. CISPR and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular EMC tests for specific products. The specifications in this standard apply to EMI receivers and spectrum analyzers. The term “measuring receiver” used in this standard refers to both EMI receivers and spectrum analyzers. Further guidance on the use of use of spectrum analyzers and scanning receivers can be found in Annex B of any one of the following standards: CISPR 16-2-1, CISPR 16-2-2 or CISPR 16-2-3.

Specification for radio disturbance and immunity measuring apparatus and methods. Radio disturbance and immunity measuring apparatus. Measuring apparatus

ICS
33.100.10
CCS
L86
发布
2010-04-30
实施
2010-04-30

This part of CISPR 16 specifies the characteristics and performance of equipment for the measurement of radiated disturbances in the frequency range 9 kHz to 18 GHz. Specifications for antennas and test sites are included. NOTE In accordance with IEC Guide 107, CISPR 16-1-4 is a basic EMC publication for use by product committees of the IEC. As stated in Guide 107, product committees are responsible for determining the applicability of the EMC standard. CISPR and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular EMC tests for specific products. The requirements of this publication apply at all frequencies and for all levels of radiated disturbances within the CISPR indicating range of the measuring equipment. Methods of measurement are covered in Part 2-3, and further information on radio disturbance is given in Part 3 of CISPR 16. Uncertainties, statistics and limit modelling are covered in Part 4 of CISPR 16.

Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements

ICS
33.100.10; 33.100.20
CCS
L86
发布
2010-04-01
实施

本规范适用于集成电路静电放电敏感度测试设备(人体放电模型 Human Body Model,简称 HBM) 的校准。

Calibration Specification for the Testing System for Microcircuits Electro-static Discharge(ESD) Sensitivity

ICS
CCS
L86
发布
2010-01-05
实施
2010-04-05

本规范适用于 SDH/PDH 传输分析仪的校准。其他同类型仪表的校准也可参照执行。

Calibration Specification for SDH/PDH Transmission Analyzer

ICS
CCS
L86
发布
2010-01-05
实施
2010-04-05

Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements

ICS
33.100.10; 33.100.20
CCS
L86
发布
2010-01-01
实施
2010-06-01

This consensus standard specifies methods, instrumentation, and facilities requirements for measurement of radio-frequency (RF) signals and RF noise emitted from unlicensed wireless devices. It does not include generic nor product-specific emission limits. Measurement methods are provided for radiated and conducted emissions that can be generated by a variety of devices, as described below. This standard does not consider test methods for unlicensed wireless devices already covered in other published standards, such as Unlicensed Personal Communication Services (UPCS) devices, which are covered in ANSI C63.17 [B1].1 In addition, many types of wireless devices are also subject to regulatory requirements concerning human exposure to RF energy; RF exposure conformity assessment methods are not considered in this standard, but are the subject of other standards, e.g., IEEE Std 1528™-2003 [B22]. This document provides standard test methods for determining compliance with regulatory requirements for many types of wireless devices. These unlicensed wireless devices include but are not limited to the following: - Remote control and security unlicensed wireless devices - Frequency hopping and direct sequence spread spectrum devices - Anti-pilferage devices - Cordless telephones - Radio frequency identification (RFID) tag readers⎯ Unlicensed National Information Infrastructure devices - Intrusion detectors - Unlicensed wireless devices operating below 30 MHz - Wireless (garage) door openers - Ultra-wideband (UWB) devices - Automatic vehicle identification systems - Other devices, e.g., with operations authorized under Part 15 of the FCC Rules and Regulations (47 CFR Part 15).2 Clause 2 and Clause 3 contain the normative references and definitions used in this standard, respectively. Clause 4 provides the specifications for the necessary test instrumentation needed for performing compliance testing. Clause 5 provides the general requirements for all standard test methods. Clause 6 provides standard test methods required for most unlicensed wireless devices. Clause 7 identifies additional tests or requirements for specific unlicensed wireless devices. Clause 8 specifies requirements for reporting test results, with special emphasis on the use of guidance from ISO/IEC 17025:2005. Annex A is an informative listing of the tests required to show compliance of a specific unlicensed wireless device. Because Annex A describes regulatory requirements for testing of unlicensed wireless devices, it serves as a key to use of this standard. Annex B is an informative example of the information to be included in a test report. Annex C is an informative discussion on instrumentation pulse desensitization considerations. Annex D provides information about detector types and functions used in EMC testing. Annex E and Annex F provide an informative glossary and related reading (bibliography), respectively. Use of the annexes and clauses applicable to a wireless device under test allows users of this standard to determine compliance of a device to national regulatory requirements. However, any test procedure identified for use by the national regulatory authority that differs from the provisions of this standard shall take precedence. Numbered cross-references used throughout this standard refer to either a specific clause or subclause of this standard; e.g., 6 refers to Clause 6, 6.2 refers to subclause 6.2, and A.2 refers to subclause A.2 of Annex A.

American National Standard for Testing Unlicensed Wireless Devices

ICS
33.070.01;33.100.10
CCS
L86
发布
2009-09-10
实施

Gives guidance on the treatment of uncertainties to those who are involved in the development or modification of CISPR electromagnetic compatibility (EMC) standards. In addition, useful background information is provided for those who apply the standards

Specification for radio disturbance and immunity measuring apparatus and methods Part 4-1: Uncertainties, statistics and limit modelling - Uncertainties in standardized EMC tests

ICS
17.220.20;33.100.20
CCS
L86
发布
2009-08-28
实施

This part of CISPR 16 is designated a basic standard, which specifies the methods of measurement of disturbance phenomena in general in the frequency range 9 kHz to 18 GHz and especially of conducted disturbance phenomena in the frequency range 9 kHz to 30 MHz.

Specification for radio disturbance and immunity measuring apparatus and methods. Methods of measurement of disturbances and immunity. Conducted disturbance measurements

ICS
33.100.10;33.100.20
CCS
L86
发布
2009-07-31
实施
2009-07-31

Specification for radio disturbance and immunity measuring apparatus and methods. Methods of measurement of disturbances and immunity. Conducted disturbance measurements

ICS
33.100.01
CCS
L86
发布
2009-07-31
实施
2009-07-31

本标准规定了公共机构办公建筑用电分类计量的分类原则、设计要求、安装要求及节能管理的要求。本标准适用于新建和已建公共机构办公建筑用电分类计量工程的设计、施工和验收。

Technical Requirements for Classified Metering of Electricity Consumption in Office Buildings of Public Institutions

ICS
17.220.20
CCS
L86
发布
2009/05/01
实施
2009/05/01

This part of CISPR 16-4 gives guidance on the treatment of uncertainties to those who are involved in the development or modification of CISPR electromagnetic compatibility (EMC) standards. In addition, this part provides useful background information for those who apply the standards and the uncertainty aspects in practice. The objectives of this part are to: a) identify the parameters or sources governing the uncertainty associated with the statement that a given product complies with the requirement specified in a CISPR recommendation. This uncertainty will be called “standards compliance uncertainty” (SCU, see 3.1.16); b) give guidance on the estimation of the magnitude of the standards compliance uncertainty; c) give guidance for the implementation of the standards compliance uncertainty into the compliance criterion of a CISPR standardised compliance test. As such, this part can be considered as a handbook that can be used by standards writers to incorporate and harmonise uncertainty considerations in existing and future CISPR standards. This part also gives guidance to regulatory authorities, accreditation bodies and test engineers to judge the performance quality of an EMC test-laboratory carrying out CISPR standardised compliance tests. The uncertainty considerations given in this part can also be used as guidance when comparing test results (and their uncertainties) obtained by using different alternative test methods. The uncertainty of a compliance test also relates to the probability of occurrence of an electromagnetic interference (EMI) problem in practice. This aspect is recognized and introduced briefly in this part. However, the problem of relating uncertainties of a compliance test to the occurrence of EMI in practice is not considered within the scope of this part. The scope of this part is limited to all the relevant uncertainty considerations of a standardized EMC compliance test.

Specification for radio disturbance and immunity measuring apparatus and methods – Part 4-1: Uncertainties, statistics and limit modelling – Uncertainties in standardized EMC tests

ICS
33.100.10;33.100.20
CCS
L86
发布
2009-02
实施

This standard specifies U.S. consensus standard methods, instrumentation, and facilities for measurement 9 of radio-frequency (RF) signals and noise emitted from electrical and electronic devices in the frequency 10 range 9 kHz to 40 GHz. It does not include generic nor product-specific emission limits. Where possible, the specifications herein are harmonized with other national and international standards used for similar purposes.

Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz

ICS
17.140.50
CCS
L86
发布
2009-01-01
实施

Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Radiated disturbances (IEC/CISPR 16-1-4:2007 + A1:2007); German version EN 55016-1-4:20

ICS
33.100.01
CCS
L86
发布
2008-09
实施
2008-09-01

Measuring relays and protection equipment - Part 22-2 : electrical disturbance tests - Electrostatic discharge tests.

ICS
29.120.70
CCS
L86
发布
2008-07-01
实施
2008-07-25

This part of CISPR 16 deals with in situ electromagnetic disturbance measurements in any environment from physically large equipment and systems excluding networks. It covers both radiated and conducted emission phenomena, and does not deal with immunity tests. This technical report is intended to be applied primarily to such physically large equipment which are not under the scope of any existing emission standards (as for example CISPR 11 and CISPR 22). It serves only as a guideline on how to deal with emissions of that equipment at the particular location of installation. It does not establish any emission requirements. NOTE 1 Although this technical report is intended to be applied to equipment which is not under the scope of any existing emission standards, it may be used also in such cases in order to serve as additional information for carrying out in situ measurements for any type of large equipment. NOTE 2 Examples of large equipment are: production machines, conveyors, large displays, aircraft simulators, traffic control equipment, etc. Due to the severe impact of the conditions existing at a particular location of operation and the use of the respective large equipment, however, it is not intended to use the measurements in the frame of type testing. NOTE 3 In general, type testing on large equipment is only possible at standardized test sites in a controlled environment. The assessment results obtained under in situ conditions are only valid for the respective individual large equipment actually measured at its particular place of installation. These results cannot be transposed to other equipment of the same type, but installed at other locations. Reference in-situ measurement distances will be given. This allows comparison of the measurement results with limits from existing relevant standards. The frequency range under consideration is from 9 kHz to 18 GHz. Dealing with biological effects on living matter is excluded from this document.

Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-5: In situ measurements of disturbing emissions produced by physically large equipment

ICS
33.100.10
CCS
L86
发布
2008-07
实施

High frequency inductive components - Non-electrical characteristics and measuring methods - Part 1: Fixed, surface mounted inductor for use in electronic and telecommunication equipment (IEC 62025-1:2007); German version EN 62025-1:2007

ICS
17.220.20;29.100.10
CCS
L86
发布
2008-02
实施
2008-02-01

Contains a recommendation on how to deal with statistics of radio interference complaints. Furthermore, it describes the calculation of limits for disturbance field strength and voltage for the measurement on a test site based on models for the distribut

Specification for radio disturbance and immunity measuring apparatus and methods Part 4-4: Uncertainties, statistics and limit modelling - Statistics of complaints and a model for the calculation of limits for the protection of radio services

ICS
17.220.20;33.100.20
CCS
L86
发布
2008-01-18
实施



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved