BS DD CEN/TS 14793-2005
固定源排放.交替法与参照法比较的实验室内验证过程

Stationary source emission — Intralaboratory validation procedure for an alternative method compared to a reference method


BS DD CEN/TS 14793-2005 发布历史

The purpose of this Technical Specification is to specify a validation procedure to show if an Alternative Method (AM) can be used as an alternative to the Standard Reference Method (SRM), both implemented to determine the same measurand. This document has been drawn up for laboratories working in air pollution measurements (and consequently examples taken from this sector are included in the appendices). In particular, this Technical Specification provides the statistical tools and different criteria to evaluate the alternative method; this does not release the person responsible for this validation from bearing technical and analytical judgement on the evaluation of the different criteria. Three steps are described in the validation procedure: ⎯ description of the AM and setting of the field of equivalence (range and type of gas matrix); ⎯ determination of the performance characteristics of the AM and calculation of the overall uncertainty where appropriate and check of compliance of the maximum overall uncertainty allowed for the SRM; ⎯ check of repeatability and lack of systematic deviation of the AM in the field in comparison with the SRM for the type of matrix defined in the field of equivalence. NOTE Some parts of the second step of the validation of the alternative method should be performed by a recognised test-house. If the AM fulfils the requirement of the procedure, then the laboratory that carried out the whole validation process is allowed to use it as a SRM in the field application where the equivalence has been demonstrated. However, if the validation process involves at least 4 different accredited laboratories performing simultaneously parallel measurements in the field, and if the AM passes with success all the tests of the procedure, then this method could be proposed to CEN, who can decide to consider this AM as a new reference method (ARM). The use of this procedure implies that a reference method has been defined by the regulator or in a contract and has been validated. This Technical Specification only considers the case of linear quantitative methods.

BS DD CEN/TS 14793-2005由英国标准学会 GB-BSI 发布于 2006-01-19,并于 2006-01-19 实施。

BS DD CEN/TS 14793-2005 在中国标准分类中归属于: X04 基础标准与通用方法,在国际标准分类中归属于: 13.040.40 固定源排放限值。

BS DD CEN/TS 14793-2005 发布之时,引用了标准

  • EN ISO 14956 空气质量.用一个规定的测量不精确性方法相比较评定所用测量方法的适合性 ISO 14956-2002
  • ISO 5725-2 ISO 5725-2-2019

BS DD CEN/TS 14793-2005的历代版本如下:

BS DD CEN/TS 14793-2005 固定源排放.交替法与参照法比较的实验室内验证过程 于 2017-01-31 变更为 BS EN 14793-2017 固定源排放. 证明替代法和参照法的等效性。

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 BS DD CEN/TS 14793-2005 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
BS DD CEN/TS 14793-2005
发布日期
2006年01月19日
实施日期
2006年01月19日
废止日期
中国标准分类号
X04
国际标准分类号
13.040.40
发布单位
GB-BSI
引用标准
ENV 13005 EN ISO 14956 ISO 5725-2
代替标准
BS EN 14793-2017
适用范围
The purpose of this Technical Specification is to specify a validation procedure to show if an Alternative Method (AM) can be used as an alternative to the Standard Reference Method (SRM), both implemented to determine the same measurand. This document has been drawn up for laboratories working in air pollution measurements (and consequently examples taken from this sector are included in the appendices). In particular, this Technical Specification provides the statistical tools and different criteria to evaluate the alternative method; this does not release the person responsible for this validation from bearing technical and analytical judgement on the evaluation of the different criteria. Three steps are described in the validation procedure: ⎯ description of the AM and setting of the field of equivalence (range and type of gas matrix); ⎯ determination of the performance characteristics of the AM and calculation of the overall uncertainty where appropriate and check of compliance of the maximum overall uncertainty allowed for the SRM; ⎯ check of repeatability and lack of systematic deviation of the AM in the field in comparison with the SRM for the type of matrix defined in the field of equivalence. NOTE Some parts of the second step of the validation of the alternative method should be performed by a recognised test-house. If the AM fulfils the requirement of the procedure, then the laboratory that carried out the whole validation process is allowed to use it as a SRM in the field application where the equivalence has been demonstrated. However, if the validation process involves at least 4 different accredited laboratories performing simultaneously parallel measurements in the field, and if the AM passes with success all the tests of the procedure, then this method could be proposed to CEN, who can decide to consider this AM as a new reference method (ARM). The use of this procedure implies that a reference method has been defined by the regulator or in a contract and has been validated. This Technical Specification only considers the case of linear quantitative methods.