This part of IEC 61000 provides guidance on principles which can be used as the basis for determining the requirements for the connection of fluctuating installations to MV, HV and EHV public power systems (LV installations are covered in other IEC documents). For the purposes of this report, a fluctuating installation means an installation (which may be a load or a generator) that produces voltage flicker and / or rapid voltage changes. The primary objective is to provide guidance to system operators or owners on engineering practices which will facilitate the provision of adequate service quality for all connected customers. In addressing installations, this document is not intended to replace equipment standards for emission limits. This report addresses the allocation of the capacity of the system to absorb disturbances. It does not address how to mitigate disturbances, nor does it address how the capacity of the system can be increased. Since the guidelines outlined in this report are necessarily based on certain simplifying assumptions, there is no guarantee that this approach will always provide the optimum solution for all flicker situations. The recommended approach should be used with flexibility and engineering judgment as far as engineering is concerned, when applying the given assessment procedures in full or in part. The system operator or owner is responsible for specifying requirements for the connection of fluctuating installations to the system. The fluctuating installation is to be understood as the customer’s complete installation (i.e. including fluctuating and non fluctuating parts). Problems related to voltage fluctuations fall into two basic categories: • Flicker effect from light sources as a result of voltage fluctuations; • Rapid voltage changes even within the normal operational voltage tolerances are considered as a disturbing phenomenon. The report gives guidance for the coordination of the flicker emissions between different voltage levels in order to meet the compatibility levels at the point of utilisation. This report primarily focuses on controlling or limiting flicker, but a clause is included to address the limitation of rapid voltage changes. NOTE The boundaries between the various voltage levels may be different for different countries (see IEV 601-01-28) [16]. This report uses the following terms for system voltage: − low voltage (LV) refers to Un ≤ 1 kV; − medium voltage (MV) refers to 1 kV < Un ≤ 35 kV; − high voltage (HV) refers to 35 kV < Un ≤ 230 kV; − extra high voltage (EHV) refers to 230 kV < Un. In the context of this report, the function of the system is more important than its nominal voltage. For example, a HV system used for distribution may be given a "planning level" which is situated between those of MV and HV systems.
IEC/TR 61000-3-7-2008由国际电工委员会 IX-IEC 发布于 2008-02。
IEC/TR 61000-3-7-2008 在中国标准分类中归属于: L06 电磁兼容,在国际标准分类中归属于: 33.100.01 电磁兼容性综合。
IEC/TR 61000-3-7-2008 电磁兼容性(EMC).第3-7部分:限值.变动载荷装置对MV、HV和EHV动力系统的连接用排放限值的评估 由 IEC/TR3 61000-3-7-1996 变更而来。
非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 IEC/TR 61000-3-7-2008 前三页,或者稍后再访问。
点击下载后,生成下载文件时间比较长,请耐心等待......
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号