BS EN ISO 5167-4:2003
用插入圆截面管道中的压差装置测量流体流量.文氏管

Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full. Venturi tubes

2022-07

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 BS EN ISO 5167-4:2003 前三页,或者稍后再访问。

您也可以尝试购买此标准,
点击右侧 “购买” 按钮开始采购(由第三方提供)。

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
BS EN ISO 5167-4:2003
发布
2003年
发布单位
英国标准学会
替代标准
BS EN ISO 5167-4:2022
当前最新
BS EN ISO 5167-4:2022
 
 
被代替标准
98/121142 DC:1998 BS EN ISO 5167-1:1992
适用范围
This part of ISO 5167 specifies the geometry and method of use (installation and operating conditions) of Venturi tubes when they are inserted in a conduit running full to determine the flowrate of the fluid flowing in the conduit. This part of ISO 5167 also provides background information for calculating the flowrate and is applicable in conjunction with the requirements given in ISO 5167-1. This part of ISO 5167 is applicable only to Venturi tubes in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. In addition, each of these devices can only be used within specified limits of pipe size, roughness, diameter ratio and Reynolds number. This part of ISO 5167 is not applicable to the measurement of pulsating flow. It does not cover the use of Venturi tubes in pipes sized less than 50 mm or more than 1 200 mm, or where the pipe Reynolds numbers are below 2 × 105. This part of ISO 5167 deals with the three types of classical Venturi tubes: a) cast; b) machined; c) rough welded sheet-iron. A Venturi tube is a device which consists of a convergent inlet connected to a cylindrical throat which is in turn connected to a conical expanding section called the “divergent”. The differences between the values of the uncertainty of the discharge coefficient for the three types of classical Venturi tube show, on the one hand, the number of results available for each type of classical Venturi tube and, on the other hand, the more or less precise definition of the geometric profile. The values are based on data collected many years ago. Venturi nozzles (and other nozzles) are dealt with in ISO 5167-3.

BS EN ISO 5167-4:2003相似标准


推荐

流量测量以及常用流量计,你都知道吗?

威力巴流量组成:包括测量变送器两部分,其中测量管用于产生变送器用于测量动、静压达到测量流体流量目的。 威力巴流量安装要求:A、测量装置安装要求有前20倍后5倍管道直径直管段要求;B、测量安装应穿过管道中心并与管道中心线垂直;C、其在管道安装方位和引敷设与孔板节流装置要求相似。 威力巴流量与停用方法:与孔板节流装置流量计相同。 ...

式湿气两相流量计校准规范》征求意见

2624.3 安装在圆形截面管道装置测量流体流量 第3部分:喷嘴和文丘里喷嘴、GB/T 2624.4 安装在圆形截面管道装置测量流体流量 第4部分:丘里、GB/T 18603 天然气计量系统技术要求、ISO TR 11583 Measurement of wet gas flow by means of pressure differential devices inserted...

孔板流量计正确选型

标准节流装置设计和生产符合国家标准GB/T 2624-93《流量测量节流装置孔板、喷嘴和文丘里测量充满圆管流体流量》和国际标准ISO 5167-1(1991)《装置测量流量 第一部分;安装在充满流体圆形截面管道孔板、喷嘴和文丘里》。...

流量仪表分类及意义

这种利用测量流量方法历史悠久,比较成熟,世界各国一般都用在比较重要场合,约占各种流量测量方式70%。发电厂主蒸汽、给水、凝结水等流量测量都采用这种表计。目前生产产品分:孔板流量计、楔形流量计、丘里流量计、平均皮托管。变面积式流量计(等压降式流量计)放在上大下小锥形流道浮子受到自下而上流动流体作用力而移动。...





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved