UL 486C BULLETINS-2006

CSDS 03/17/2006 (10p); CSDS 01/27/2006 (10p)


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 UL 486C BULLETINS-2006 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 UL 486C BULLETINS-2006 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 




购买全文,请联系:


标准号
UL 486C BULLETINS-2006
发布日期
2006年01月01日
实施日期
废止日期
国际标准分类号
29.120.20
发布单位
US-UL
适用范围
1 This Standard applies to hand- or tool-applied splicing wire and cable connectors intended for use with all alloys of copper or aluminum conductors, or both, in accordance with the Canadian Electrical Code Part I, C 22.1, in Canada, the National Electrical Code, NFPA-70, in the United States of America, or the Standard for Electrical Installations, NOM-001-SEDE, in Mexico, as follows: a) connectors intended to hold two or more conductor(s); b) connectors intended for use in appliances and equipment that comply with the requirements for such appliances and equipment; c) connectors intended for use with 6 AWG (13.3 mm2) or smaller conductors; and d) uninsulated connectors that are used in circuits rated 8000 V and less. Note: Examples of splicing wire connectors include twist-on connectors, insulation-piercing or displacement connectors, spring-action connectors, tool-applied crimp, mechanical set-screw connectors, etc. 2 This Standard is intended for splicing wire connectors suitable for use with conductors in the size ranges as follows: a) Aluminum: 1) 12 AWG (3.3 mm2) and 10 AWG (5.3 mm2) solid; and 2) 12 AWG (3.3 mm2) to 6 AWG (13.3 mm2) stranded, Class B concentric, compressed, and unidirectional lay compact. In M倄ico, the use of aluminum conductors is permitted only with thermoset insulation and for sizes of 6 AWG (13.3 mm2) and higher. b) Copper: 1) 30 AWG (0.05 mm2) to 10 AWG (5.3 mm2) solid; and 2) 30 AWG (0.05 mm2) to 6 AWG (13.3 mm2) stranded, Class B concentric and compressed, and Class C concentric. c) Compact-stranded copper conductors: In Canada and Mexico, for 8 AWG (8.4 mm2) and 6 AWG (13.3 mm2). In the United States this is not applicable. d) Rigid (solid and stranded) metric wire falling within the ranges of the above AWG sizes. Note: For example, a connector rated for 6 AWG (13.3 mm2) - 14 AWG (2.1 mm2) may be additionally rated for 10 - 2.5 mm2. e) Other class and strand configurations as indicated by marking. 3 These requirements cover splicing wire connectors intended for: a) copper-to-copper; b) aluminum-to-aluminum; c) copper-to-aluminum conductor combinations intended for intermixing of conductors and dry locations only; or d) all of the above. 4 This Standard is intended for splicing wire connectors suitable for currents not exceeding the ampacity of insulated conductors rated 75 鳦 or 90 鳦, in accordance with the rating of the connector. 1.5 This Standard does not apply to: a) splicing wire connectors intended for direct burial; b) insulated splicing wire connectors intended for use at voltage levels in excess of 600 V (1000 V in a sign or luminaire); c) terminal wire connectors; d) wire binding screw terminals; e) built-in terminal connectors on devices rated less than 30 A and intended for outlet box mounting or having provision for stress relief; f) built-in terminal connectors on devices having integral cable clamps; g) flat quick connect terminals; and h) soldering lugs.




Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号