ASTM D7203-2011
使用加热的二极管传感器筛分三氯乙烯污染物的标准试验方法

Standard Practice for Screening Trichloroethylene (TCE)-Contaminated Media Using a Heated Diode Sensor


ASTM D7203-2011 中,可能用到以下仪器设备

 

SS2000震动筛分仪

SS2000震动筛分仪

北京绿绵科技有限公司

 

电动筛选器

电动筛选器

山东盛泰仪器有限公司

 

Sievecal筛网校准校测分析仪

Sievecal筛网校准校测分析仪

安东帕(上海)商贸有限公司

 

SubsieveAutoSizer全自动费氏粒径测试仪

SubsieveAutoSizer全自动费氏粒径测试仪

麦克默瑞提克(上海)仪器有限公司

 

Sievecal筛网校准校测分析仪

Sievecal筛网校准校测分析仪

DT/仪思奇(北京)科技发展有限公司

 

Hosokawa Alpine e200LS 气流筛分仪

Hosokawa Alpine e200LS 气流筛分仪

上海凯来仪器有限公司

 

 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 ASTM D7203-2011 前三页,或者稍后再访问。

点击下载后,生成下载文件时间比较长,请耐心等待......

 



标准号
ASTM D7203-2011
发布日期
2011年
实施日期
废止日期
中国标准分类号
Z18
国际标准分类号
13.080.10 (Chemical characteristics of soil)
发布单位
US-ASTM
适用范围

The heated diode sensor device used in this practice is selective for HVOCs. Other electronegative compounds, such as alcohols, ketones, nitrates, and sulfides, may cause a positive interference with the performance of the heated diode sensor to detect HVOCs, but to do so, they must be present at much higher concentrations than the HVOCs.

Note 28212;For volatile organic compound (VOC) screening purposes, a flame ionization detector (FID) selectively responds to flammable VOCs; a photoionization detector (PID) selectively responds to VOCs having a double bond; and a heated diode sensor selectively responds to halogenated VOCs.

This practice can be used for screening media known to contain TCE to estimate the concentration of TCE in the media. Procedure A is to be used for screening soil known to contain TCE and Procedure B is to be used for screening water known to contain TCE. Both Procedures A and B involve measuring the TCE concentration in the headspace above a sample. From this measurement, an estimated concentration of TCE in the sample can be determined. Any TCE remaining in the sample is not measured by this practice. Any other HVOC present in the sample will be reported as TCE.

This practice can also be used for screening the headspace above a soil or water suspected of containing HVOC contamination to indicate the presence or absence of HVOC contamination in the soil (Procedure A) or water (Procedure B). Any HVOC contamination remaining in the sample is not detected by this practice.

Detection Limit8212;The detection limit of the heated diode sensor for TCE is 0.1 mg/m3 in air, based on a signal-to-noise ratio of 2. For a 25-g TCE-contaminated soil sample in a 250-mL container, the detection limit of Procedure A for TCE is 0.001 mg/Kg, assuming complete partitioning of TCE into the headspace. For a 25-g TCE-contaminated water sample in a 250-mL container, the detection limit of Procedure B for TCE is 0.001 mg/L, assuming complete partitioning of TCE into the headspace.

This practice can be used to screen moist soil samples and water samples. Water vapor does not interfere with the performance of the heated diode sensor.

Hydrocarbon fuels, including fuels containing aromatic compounds, such as gasoline, are not detected by the practice.

1.1 This practice describes procedures for screening media known to contain the halogenated volatile organic compound (HVOC), trichloroethylene (TCE). Procedure A is to be used for screening soil known to contain TCE and Procedure B is to be used for screening water known to contain TCE.

1.1.1 Both Procedures A and B involve measuring the TCE concentration in the headspace above a sample using a heated diode sensor device. From this measurement, an estimated concentration of TCE in the sample can be determined. Any TCE remaining in the sample is not measured. Any other HVOC present in the sample will be reported as TCE.

1.2 Procedure A can also be used for screening the headspace above a soil suspected of containing HVOC contamination to indicate the presence or absence of HVOC contamination in the soil. Procedure B can also be used for screening the headspace above a water suspected of containing HVOC contamination to indicate the presence or absence of HVOC contamination in the water. For both procedures, any HVOC contamination remaining in the soil or water is not detected by this practice.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.3.1 Exception8212;Certain inch-pound units are provided for information only.

1.4 ......